VAX Maintenance Handbook, VAX-11/750

Company:Digital Equipment Corporation
Part:EK-VAXV3-HB-001
Date:1983-03
Keywords:

Table of Contents

  • Chapter 1 Introduction
    • Introduction
    • VAX-11/750 System Hardware Manuals
    • VAX-11/750 Peripheral Manuals
    • VAX-11/750 Maintenance Philosophy
    • CPU Modules
    • CPU Options
    • The Remote Diagnostic Facility
    • Contacting the DDC
  • Chapter 2 System Register
    • CMC (MS750) Registers
    • Control/Status Register 0 (CSR 0)
    • Control/Status Register 1 (CSR 1)
    • Control/Status Register 2 (CSR 2)
    • CPU (KA750) Processor Status Longword (PSL)
    • Internal Processor Register (IPR) Summary
    • Internal Processor Registers
    • Interval Register Hardware Usage
    • TB Register Bit Fields
    • Cache Register Bit Fields
    • TB and Cache Control/Status Register Bit Fields
    • WCS (KU750) Register Data Write Format
    • UBI and SUB Registers
    • UBI or SUB (DW750) Control/Status Register (CSR)
    • CSR Addresses
    • UBI or SUB MAP Register Data
    • MAP Register Addresses
    • UNIBUS to CMI Address Translation
    • UET Registers
    • IPEC Registers
    • UNIBUS Address and Data Registers
    • Control Register 1 (CR1)
    • Control Register 2 (CR2)
    • MBA (RH750) Registers
    • MBA Internal Registers
    • Control Register (CR) - F28004
    • Status Register (SR) - F28008
    • Virtual Address Register (VAR) - F2800C
    • Byte Count Register (BCR) - F28010
    • Diagnostic Register (DR) - F28014
    • Command Address Register (CAR) - F2801C
    • MBA MAP Register Data - F28800-F28BFC
    • MBA to CMI MAP Address Translation
    • MASSBUS External Device Registers
    • Drive Control Register (R0) - F28400
    • Attention Summary Register (R4) - F28410
    • DZ11 Registers
    • RK611 Registers
    • DR750 Registers
    • DR750 Command Block
    • DR750 Command Packet
    • DR750 DCR Register - Read Format
    • DR750 DCR Register - Write Format
    • DR750 Status Longword
    • DR750 Utility Register
    • DI Clock Data Rate Selection
    • DR750 Device Vectors
  • Chapter 3 Modules and Gate Arrays
    • VAX-11/750 Module Utilization
    • CMC Gate Array Layout (L0011)
    • CMC Gate Array Layout (L0016)
    • CMC Gate Array Description
    • Bootstrap Device ROMs
    • ROM Starting Microaddresses
    • DPM Gate Array Layout (L0002)
    • DPM Gate Array Description
    • MIC Gate Array Layout (L0003)
    • MIC Gate Array Description
    • UBI Gate Array Layout (L0004)
    • SUB Gate Array Layout (L0010)
    • UBI and SUB Gate Array Description
    • MBA Gate Array Layout (L0007)
    • MBA Gate Array Description
    • FPA Gate Array Layout (L0001)
    • FPA Gate Array Description
    • Gate Array Part Number/Module Cross-Reference
    • CCS Module with WCS (L0005)
    • CCS Module ROM Layout
    • UET Component Layout
    • TU58 Interface Component and Jumper Layout
  • Chapter 4 Configuration and Cabling
    • VAX-11/750 System Configurations
    • Dual RK07 System
    • Dual RK07 System with TS11
    • RM03/TS11 System
    • RM80/TS11 System
    • System Cabling Diagrams
    • TU58 and Front Panel Cables
    • MASSBUS Cables
    • UNIBUS Cables
    • DZ11 Distribution Panel
    • DZ11 Distribution Terminals
    • VAX-11/750 Power System
    • System Interconnection Diagram
    • VAX-11/750 Power Supply
    • AC Power Controller Panel
    • REMOTE/LOCAL Switch
    • H7104 Power System Block Diagram
    • AC Power Distribution
    • DC Power Distribution
    • Power System Sensing
    • +2.5 V Power Supply Block Diagram
    • +5 V Power Supply Block Diagram
    • Applying System Power
    • CPU Cabinet Power Requirements
    • Standard Power Plugs and Receptacles
  • Chapter 5 Bootstrapping and Operation
    • VAX-11/750 Front Panel
    • Console Panel Indicators
    • Console Switch Functions
    • Console Bootstrap Flow
    • Console Subsystem Action on a Boot
    • Bootstrap Sequence
    • Input Arguments
    • Software Boot Control Flags
    • VMB Primary Boot Failures
    • Console Commands
    • Console Command Error Codes
    • Console Halt Codes
    • Boot, Power-Up, and Initialization Halt Codes
    • Microverify Error Codes
    • BOOT58 Commands
  • Chapter 6 RDM and Microdiagnostics
    • RDM Installation
    • RDM Hardware
    • Preinstallation
    • Installation Procedure
    • Installation Verification
    • RDM Removal
    • Installation Outside the United States
    • RDM Cabling
    • Filtered Cable Installation
    • Modem Cabling
    • RDM/Modem Signals
    • Selected CPU Backplane Signals
    • RDM Installation Tests
    • VAX CPU Test
    • VAX Memory Bus Test
    • VAX Control Store Parity Check
    • Microbreak Point and Trace
    • Microdiagnostic Run Test
    • RDM Commands
    • RDM Troubleshooting Flow
    • RDM Control Key Functions
    • RDM Console Commands
    • RDM Console Error Codes
    • VAX-11/750 Diagnostics
    • Micromonitor (MICMON) Commands
    • Visibility Bus (VBUS) Signals
  • Chapter 7 Block Diagrams
    • VAX-11/750 Basic Diagram
    • VAX-11/750 System Diagram
    • CMC (MS750) Basic Diagram
    • CMC (MS750) Block Diagram
    • DPM Basic Diagram
    • DPM Block Diagram
    • MIC Block Diagram
    • TB Functional Diagram
    • Cache Functional Diagram
    • CCS Block Diagram
    • WCS (KU750) Block Diagram
    • CCS/WCS Microword
    • UBI Block Diagram
    • UBI Microword
    • SUB (DW750) Block Diagram
    • SUB Microword
    • UDP Data Flow Block Diagram
    • UBI Interface to First UNIBUS Lines
    • SUB Interface to Second UNIBUS Lines
    • MBA (RH750) Block Diagram
    • MDP Data Flow Block Diagram
    • FPA (FP750) Basic Diagram
    • FPA (FP750) Block Diagram
    • TU58 Drive/Cartridge Diagram
    • TU58 Cassette Tape Block Locations
    • TU58 Block Diagram
    • RDM Block Diagram
  • Chapter 8 CMI, UNIBUS, and MASSBUS
    • CMI Physical Address Map
    • CMI Address and Data Format
    • CMI Address Format
    • CMI Byte Mask and Function Bits
    • CMI Data Format
    • CMI Signal Description
    • VAX-11/750 Backplane
    • CMI Signal Pin Assignments on Option Slots
    • Bus Grant Chain and Continuity Jumpers
    • MBA Installation Jumpers
    • MBA Select Jumpers
    • MBA CMI Arbitration Jumpers
    • MBA Interrupt Priority Plug
    • Reserved Arbitration Jumpers
    • Module Block Layout
    • Module Pin Breakouts
    • CPU Backplane from Pin Side
    • Backplane Connector Housing Installation Diagram
    • UBI and SUB Physical Address Space
    • First and Second UNIBUS Register Summary
    • Fixed Device Address and Vector Assignments
    • Floating Address UNIBUS Devices
    • Floating Vector UNIBUS Devices
    • UNIBUS Signal Description
    • UNIBUS Cable Pin Assignments
    • MBA Physical Address Space
    • MBA and MASSBUS Register Summary
    • MBA Register Offsets
    • MBA Physical Base Addresses
    • MBA Internal Register Offsets
    • MBA MAP Register Offsets
    • MBA External (MASSBUS) Register Offsets
    • MASSBUS Signal Description
    • MASSBUS Cable Pin Assignments
  • Chapter 9 Troubleshooting Aids
    • System Troubleshooting Flow
    • UNIBUS Troubleshooting with the UET or IPEC
    • The FILEX Utility
    • The WRITEBOOT Utility
    • Machine Checks
    • Translation Buffer or Bus Error
    • Control Store Parity Error
    • Writing SPRs
    • General Guidelines
    • General Notes
    • VAX-11/750 Troubleshooting Tips
    • DW750 Installation
    • UNIBUS Exerciser (UBE) on the Second UNIBUS
  • Chapter 10 Charts and Macros
    • System Scratchpad Logic
    • RTEMP and GPR Functions
    • Privileged IPR and MTEMP Functions
    • RSRC Assignments
    • MSRC Assignments
    • Charts
    • Macros

Copies

Address: http://manx-docs.org/collections/antonio/dec/ek-vaxv3-hb-001.pdf
Site: Antonio Carlini's Scans
Format: PDF
Size: 27880277 bytes (26.6 MiB)
MD5: 8b6b5cf39258cc0a0a9952d2c168a1a5