Appendix A. Technical Specifications and Pinouts

This appendix contains technical specification information about your system, as follows:

System-level Specifications

Table A-1 summarizes the Altix 450 system configuration ranges. Note that while each compute/memory board can house either one or two processor sockets; each socket holds two processor “cores”.

Table A-1. Altix 450 System Configuration Ranges

Category

Minimum

Maximum

Processor cores

4[a]

76

Individual Rack Units (IRUs)

1 per rack

4 per system image[b]

Compute/memory blade DIMM capacity

4 DIMMs per blade

12 DIMMs per blade

System main memory DIMMs

4 per system image

228 per system image

Number of base I/O blades

One per IRU

4 per system image

[a] Single-socket compute blades support two cores each.

[b] Two complete systems of four IRUs each can be installed in the same 42U tall rack.


Physical Specifications

Table A-2 shows the physical specifications of the Altix 450 system in a 42U rack.

Table A-2. Altix 450 Tall Rack System Physical Specifications

Feature

Specification

Dimensions for a single tall (42U) rack system, including doors and side panels

Height: 79.5 in. (201.9 cm)
Width: 25.8 in. (65.5 cm)
Depth: 43.45 in. (110. 4 cm)

Shipping dimensions

Height: 81.5 in. (207 cm)
Width: 42 in. (106.7 cm)
Depth: 52 in. (132.1 cm)

Weight of full rack (maximum)

~1450 lb (658 kg)

Shipping weight (maximum)

~1600 lb (727 kg)

Access requirements

Front

Rear

Side

 

 

48 in. (121.9 cm)

48 in. (121.9 cm)

None

Individual Rack Unit (IRU) enclosure specifications

Dimensions: 6.68 in high x 17.5 in wide x 17 in deep

(22 cm high x 44.45 cm wide x 43.2 cm deep)

Weight: ~130 lbs. (59.1 kg)

Table A-3 lists the physical specifications of the Altix 450 system in a 20U rack.

Table A-3. Altix 450 Short Rack System Physical Specifications

Feature

Specification

Dimensions for a single short (20U) rack system, including doors and side panels

Height: 41.8 in. (106.2 cm)
Width: 25.8 in. (65.5 cm)
Depth: 40.9 in. (103.9 cm)

Shipping dimensions

Height: 47.5 in. (120.7 cm)
Width: 31.25 in. (79.4 cm)
Depth: 49.5 in. (125.7 cm)

Weight of full rack (maximum)

750 lb (340 kg)

Shipping weight (maximum)

862 lb (391 kg)

Access requirements

Front

Rear

Side

 

 

48 in. (121.9 cm)

48 in. (121.9 cm)

None

Individual Rack Unit (IRU) enclosure specifications

Dimensions: 8.68 in high x 17.5 in wide x 17 in deep

(22 cm high x 44.45 cm wide x 43.2 cm deep)

Weight: ~130 lbs. (59.1 kg)


Environmental Specifications

Table A-4 lists the environmental specifications of the 42U rack system. Table A-5 provides the environmental information for the 20U system.

Table A-4. Environmental Specifications (42U Rack)

Feature

Specification

Temperature tolerance
(operating)

+5 °C (41 °F) to +35 °C (95 °F) (up to 1500 m / 5000 ft.)
+5 °C (41 °F) to +30 °C (86 °F) (1500 m to 3000 m /5000 ft. to 10,000 ft.)

Temperature tolerance
(non-operating)

-40 °C (-40 °F) to +60 °C (140 °F)

Relative humidity

10% to 90% operating (no condensation)
8% to 95% non-operating (no condensation)

Heat dissipation

Altix 450 (42U rack)

 

59.71 kBTU/hr maximum (based on 17.5 kW)

Cooling requirement

Ambient air cooling

Air flow: intake (front), exhaust (rear)

Approximately 1400 CFM (normal operation)

Maximum altitude

10,000 ft. (3,049 m) operating
40,000 ft. (12,195 m) non-operating

Acoustical noise level

Less than 65 dBa maximum (with doors)

.

Table A-5. Environmental Specifications (20U Rack)

Feature

Specification

Temperature tolerance
(operating)

+5 °C (41 °F) to +35 °C (95 °F) (up to 1500 m / 5000 ft.)
+5 °C (41 °F) to +30 °C (86 °F) (1500 m to 3000 m /5000 ft. to 10,000 ft.)

Temperature tolerance
(non-operating)

-40 °C (-40 °F) to +60 °C (140 °F)

Relative humidity

10% to 90% operating (no condensation)
8% to 95% non-operating (no condensation)

Heat dissipation

Altix 450

 

29.86 kBTU/hr maximum (based on 8.75 kW)

Cooling requirement

Ambient air cooling only

Air flow: intake (front), exhaust (rear)

Approximately 750 CFM (normal operation)

Maximum altitude

10,000 ft. (3,049 m) operating
40,000 ft. (12,195 m) non-operating

Acoustical noise level

Less than 65 dBa maximum (with doors)


Power Specifications

Table A-6 shows the power specifications for the system.

Table A-6. Power Specifications

Feature

Specification

Single-phase power requirements

Voltage

Frequency

Power

 

200-240V (180-254 VAC min/max)

50-60 Hz

17.5 kW max per tall rack

8.75 kW max per short rack

Hold-up time

16 ms

Total harmonic distortion

Less than 10% at full load


I/O Port Specifications

This section contains specifications and port pinout information for the base I/O ports of your system, as follows:

Ethernet Port

The system auto-selects the Ethernet port speed and type (duplex vs. half-duplex) when the server is booted, based on what it is connected to. Figure A-1 shows the Ethernet port.

Figure A-1. Ethernet Port

Ethernet Port

Table A-7 shows the cable pinout assignments for the Ethernet port operating in 10/100-Base-T mode and also operating in 1000Base-T mode.

Table A-7. Ethernet Pinouts

Ethernet 10/100Base-T Pinouts

Gigabit Ethernet Pinouts

Pins Assignment

Pins Assignment

1 Transmit +

1 Transmit/Receive 0 +

2 Transmit –

2 Transmit/Receive 0 –

3 Receive +

3 Transmit/Receive 1 +

4 NU

4 Transmit/Receive 2 +

5 NU

5 Transmit/Receive 2 –

6 Receive –

6 Transmit/Receive 1 –

7 NU

7 Transmit/Receive 3 +

8 NU

8 Transmit/Receive 3 –

NU = Not used

Serial Ports

The IRU modules have 9-pin serial interface connectors. These ports are for console interface and are capable of transferring data at rates as high as 230 kbps. Other features of the ports include the following:

  • Programmable data, parity, and stop bits

  • Programmable baud rate and modem control

Figure A-2 shows a serial port example.

Figure A-2. Serial Port Connector

Serial Port Connector

Table A-8 shows pinout assignments for the 9-pin male DB-9 connector.

Table A-8. Serial Port Pinout

Pin

Assignment

Description

1

DCD

Data carrier detect

2

RXD

Receive data

3

TXD

Transmit data

4

DTR

Data terminal ready

5

GND

Signal ground

6

DSR

Data set ready

7

RTS

Request to send

8

CTS

Clear to send

9

RI

Ring indicator


External SAS/SATA Port Connector 

Figure A-3 shows the connector pin locations for the external single-channel Serial Attached SCSI (SAS) and Serial Advanced Technology Attachment (SATA) connector. This combined technology connector is used to support optional external storage. Table A-9 lists the pin assignments for the 14-pin SAS/SATA connector.

Figure A-3. Pin Number Locations for External SAS/SATA Port

Pin Number Locations for External SAS/SATA Port

Table A-9. SAS/SATA Pin Assignments

Pin Number

Signal Name

Pin Number

Signal Name

1

Gnd

8

Gnd

2

2tx_h

9

3tx_h

3

2tx_1

10

3tx_1

4

Gnd

11

Gnd

5

2rx_1

12

3rx_1

6

2rx_h

13

3rx_h

7

Gnd

14

Gnd


USB Type A Connector

Figure A-4 shows the USB type A connector provided on the base I/O that supports general USB applications and optional keyboard and mouse configurations.

Table A-10 lists the pin assignments for the USB type A connector.

Figure A-4. Pin Number Locations for USB Type A Connector

Pin Number Locations for USB Type A Connector

Table A-10. Pin Assignments for USB Type A Connector

Signal

Color

Pin Number

VCC

Red

1

-Data

White

2

+Data

Green

3

Ground

Black

4