List of Figures
| Table of Contents | List of Figures | List of Tables |
- Figure 1-1. 30-amp Single-phase Power Receptacle for North American Sites
- Figure 1-2. 32-amp Single-phase Power Plug for International Sites
- Figure 1-3. Dimensions of Tall Rack Shipping Crate
- Figure 1-4. Dimensions of Short Rack Shipping Crate
- Figure 1-5. Removing a
Short Rack from the Shipping Crate
- Figure 1-6. Removing a Tall Rack from the Shipping Crate
- Figure 1-7. Reattaching the Tall Rack Doors
- Figure 1-8. Leveling Bolts
- Figure 1-9. Seismic Tie-down Attachment Points
- Figure 1-10. IRU Connection Plate for Desktop Systems
- Figure 1-11. Mounting Hole Pattern of Rack Rails
- Figure 1-12. Installing the Shelf Rails in the Rack
- Figure 1-13. Securing the Module to the Front of the Rack
- Figure 1-14. NUMAlink Cabling an IRU to an Additional IRU
- Figure 1-15. Power-Supply Connectors on the IRU Module
- Figure 1-16. Connecting an Unracked IRU System to a Power Source
- Figure 1-17. Connecting Multiple Modules to a PDU
- Figure 1-18. Optional Three-Phase PDU Example
- Figure 1-19. Location of the L1 Console Port
- Figure 1-20. PDU Circuit Breakers Example
- Figure 1-21. Location of the Power Button
- Figure 1-22. L1 Front Panel Functions
- Figure 2-1. IRU Power Supply Cable Location Example
- Figure 2-2. Single-Phase Rack PDU Circuit Breaker Switches
- Figure 2-3. IRU L1 Controller Display Location Example
- Figure 2-4. 2D Graphics Card Location in IA2 (base I/O) Blade
- Figure 3-1. SGI Altix 450 System (Short Rack)
- Figure 3-2. SGI Altix 450 Server
System (Tall Rack)
- Figure 3-3. Blade, IRU and Rack Components
- Figure 3-4. Functional Block Diagram of the Individual Rack Unit (IRU)
- Figure 3-5. Blade Node Local Compute/Memory Block Diagram Example
- Figure 3-6. Altix 450
IRU System Components Example
- Figure 4-1. SGI Altix 450 System Control Network (Example)
- Figure 4-2. L1 Front Panel
- Figure 4-3. Ethernet Switch System Controller Block Diagram (Example)
- Figure 5-1. Tall (42U) Altix Rack and Front Lock
- Figure 5-2. Short (20U) Altix Rack (Rear View)
- Figure 6-1. Removing the L1 Controller Panel
- Figure 6-2. Replacing the L1 Controller Panel
- Figure 6-3. Removing an IRU Power Supply
- Figure 6-4. Replacing an IRU Power Supply
- Figure 6-5. IRU Fan Assembly (Blowers)
- Figure 6-6. Removing a Fan From the IRU
- Figure 6-7. Replacing an IRU Fan
- Figure 6-8. Removing a Compute/Memory Blade From the IRU
- Figure 6-9. Replacing a Compute/Memory Blade in the IRU
- Figure 6-10. 12-DIMM Board Group Locations Diagram
- Figure 6-11. 12-DIMM Board Memory Slot Location Example
- Figure 6-12. 8-DIMM Board Group Locations Diagram
- Figure 6-13. 8-DIMM Board Memory Slot Location Example
- Figure 6-14. DVD Removal from IA Blade
- Figure 6-15. DVD Drive Replacement in the IA Blade
- Figure 6-16. Comparison of PCI/PCI-X Connector with PCI Express Connectors
- Figure 6-17. Removing a Card Carrier From the Three-Slot Blade
- Figure 6-18. Extracting the Carrier Metal Filler Plate
- Figure 6-19. Adjusting the Carrier Guide Bar
- Figure 6-20. Mounting Card in Carrier
- Figure 6-21. Mounting Half-height PCI Card into Carrier
- Figure 6-22. Moving Carrier Guide Bar to Secure Half-height PCI Card
- Figure 6-23. Installing the Bracket to Secure a Half-height PCI Card
- Figure 6-24. Installing a Card in a Slot
- Figure 6-25. Seating the Card in the Slot
- Figure 6-26. Removing the Card Access Panel From the IA Blade
- Figure 6-27. Replacing the IA Blade PCI Access Door
- Figure 6-28. Location of Disk Drive Bays on IA/IA2 Blade
- Figure 6-29. Removing a Disk Drive
- Figure 6-30. Replacing a Disk Drive
- Figure 7-1. Compute Blade Status LED Locations
- Figure 7-2. Full Support Sequence
- Figure A-1. Ethernet Port
- Figure A-2. Serial Port Connector
- Figure A-3. Pin Number Locations for External SAS/SATA Port
- Figure A-4. Pin Number Locations for USB Type A Connector
- Figure B-1. VCCI Notice (Japan Only)
- Figure B-2. Chinese Class A Regulatory Notice
- Figure B-3. Korean Class A Regulatory Notice