DMR11 Synchronous Controller Technical Manual

Company:Digital Equipment Corporation
Part:EK-DMR11-TM-002
Date:1981-01
Keywords:

Table of Contents

  • Chapter 1 Introduction
    • 1.1 Scope
    • 1.2 DMR11 General Description
    • 1.3 DMR11 System Operation
      • 1.3.1 Command Structure
      • 1.3.2 Input Commands
      • 1.3.3 Output Commands
      • 1.3.4 DMR11 Operation Sequencing
      • 1.3.5 Maintenance Mode Operation
    • 1.4 General Specifications
      • 1.4.1 Power Requirements
      • 1.4.2 Environmental Requirements -- All DMR11s
    • 1.5 EIA Standards Overview (RS-449 vs RS-232-C)
  • Chapter 2 Installation
    • 2.1 Scope
    • 2.2 Unpacking and Inspection
    • 2.3 Installation Considerations
    • 2.4 Preinstallation Considerations
      • 2.4.1 System and Device Placement
        • 2.4.1.1 System Placement
        • 2.4.1.2 Device Placement
      • 2.4.2 System Requirements
    • 2.5 Microprocessor Installation
      • 2.5.1 Backplane Considerations
      • 2.5.2 M8207-RA Considerations
      • 2.5.3 M8207-RA Insertion
    • 2.6 Line Unit Installation
      • 2.6.1 M8203 Considerations
      • 2.6.2 M8203 Insertion
    • 2.7 DMR11 System Testing
      • 2.7.1 Functional Diagnostic Testing
      • 2.7.2 DECX11 System Exerciser
      • 2.7.3 Final Cable Connections
      • 2.7.4 DMR11 Link Testing
    • 2.8 DMR11-XX Installation Check-Off List
  • Chapter 3 Programming
    • 3.1 Introduction
    • 3.2 Command Structure
      • 3.2.1 Control and Status Registers
      • 3.2.2 Initialization
      • 3.2.3 Input Commands Overview
        • 3.2.3.1 Input Commands Handshaking
        • 3.2.3.2 Modem Status Read
      • 3.2.4 Output Commands Overview
        • 3.2.4.1 Output Command Handshaking
    • 3.3 Input Commands
      • 3.3.1 Base In
      • 3.3.2 Control In
      • 3.3.3 Receive Buffer Address/Character Count In (RBA/CCI)
      • 3.3.4 Transmit Buffer Address/Character Count In (TBA/CCI)
      • 3.3.5 Halt Request Command
    • 3.4 Output Commands
      • 3.4.1 Receive Buffer Address/Character Count Out (RBA/CCO)
      • 3.4.2 Transmit Buffer Address/Character Count Out (TBA/CCO)
      • 3.4.3 Control Out
    • 3.5 Programming Techniques
      • 3.5.1 Input Command Sequence
      • 3.5.2 Base In Command with Resume Feature
      • 3.5.3 Distinguishing DMR11 from DMC11
      • 3.5.4 DDCMP Maintenance Mode Operation
        • 3.5.4.1 Data Transfer
        • 3.5.4.2 Unattended System Control
    • 3.6 Base Table Counters
    • 3.7 Modem Control
      • 3.7.1 Modem Control Implemented in M8203
        • 3.7.1.1 Modem Ready Lockout of RTS
        • 3.7.1.2 Half-Duplex Mode
      • 3.7.2 Modem Control Implemented in DMR11 Microprogram
        • 3.7.2.1 Auto-Answer
        • 3.7.2.2 Data Set Ready Glitch
        • 3.7.2.3 RTS-CTS Delay
        • 3.7.2.4 Loss of Carrier Detect
        • 3.7.2.5 Receiver Inactive Check
        • 3.7.2.6 Modem Status Read During Input Command
        • 3.7.2.7 Data Terminal Ready Control
    • 3.8 DMR11 Data Link Functions
  • Chapter 4 Service
    • 4.1 Scope
    • 4.2 Maintenance Philosophy
    • 4.3 Maintenance Functions/Maintenance Modes
      • 4.3.1 Maintenance Register (BSEL1)
      • 4.3.2 Maintenance Modes
        • 4.3.2.1 Maintenance Modes
        • 4.3.2.2 System Test
        • 4.3.2.3 Single Step Internal Maintenance Mode
        • 4.3.2.4 System Test Internal Maintenance Mode
        • 4.3.2.5 External Maintenance Mode
      • 4.3.3 Maintenance (LED) Indicators
    • 4.4 Preventive Maintenance (PM)
    • 4.5 Corrective Maintenance on a PDP-11 Processor
      • 4.5.1 CZDMP*/CZDMQ*
      • 4.5.2 CZDMR*/CZDMS*
      • 4.5.3 CZDMI*
      • 4.5.4 DMR11 Microdiagnostic Error Reporting
      • 4.5.5 ZDMO** -- DMC11/DMR11 Overlay for Interprocessor Test Program (ITEP)
      • 4.5.6 DEC/X11 DMC11 Module
      • 4.5.7 Soft Error Reports Under DEC/X11
      • 4.5.8 Examination of DMR11 Internal Components
    • 4.6 Corrective Maintenance on a VAX-11/780
      • 4.6.1 EVDXA COMM Microprocessor Repair Level Diagnostics
      • 4.6.2 EVDMA Repair Level Diagnostics
      • 4.6.3 EVDCA REV** VAX-11/780 Synchronous Link Level Two Diagnostics
      • 4.6.4 Examination of DMR11 Internal Components
  • Appendix A Floating Device Addresses and Vectors
    • A.1 Floating Device Addresses
    • A.2 Floating Vector Addresses
    • A.3 Examples of Device and Vector Address Assignment
  • Appendix B DDCMP in a Nutshell
    • B.1 DDCMP
      • B.1.1 Controlling Data Transfers
      • B.1.2 Error Checking and Recovery
      • B.1.3 Character Coding
      • B.1.4 Data Transparency
      • B.1.5 Data Channel Utilization
    • B.2 Protocol Description
    • B.3 Message Format
  • Appendix C Diagnostic Supervisor Summary
    • C.1 Introduction
    • C.2 Versions of the Diagnostic Supervisor
    • C.3 Loading and Running a Supervisor Diagnostic
      • C.3.1 Five Steps to Run a Supervisor Diagnostic
    • C.4 Supervisor Commands
      • C.4.1 Command Switches
      • C.4.2 Control/Escape Characters Supported
    • C.5 What is the Setup Utility?
  • Appendix D Microcode Overview
    • D.1 Introduction
    • D.2 Functional Hardware
    • D.3 DMR11 Microprogram
      • D.3.1 Microprogram Message Processing
      • D.3.2 Transmit Process
      • D.3.3 Receive Process
  • Appendix E Bootstrap Test Under ITEP
    • E.1 Remote Load Detect
    • E.2 DMR11 Setup for Remote Load Detect
      • E.2.1 DMR11 Addressing
      • E.2.2 DMR11 Line Unit Setup
    • E.3 Procedure to Test Remote Load Detect Under ITEP
    • E.4 Procedure to Test Down-Line Load Under ITEP

Copies

Address: http://www.computer.museum.uq.edu.au/pdf/EK-DMR11-TM-002%20DMR11%20Synchronous%20Controller%20Technical%20Manual.pdf
Site: Wilber Williams' Computer Museum
Format: PDF
Size: 39371859 bytes (37.5 MiB)
MD5: db0025fb2b7e78993940636c9a0c3540
Mirrors:
 
Address: http://bitsavers.org/pdf/dec/unibus/DMR11/EK-DMR11-TM-002_Jan81.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 7508889 bytes (7.2 MiB)
MD5: ccb80244813cbaff9b2f0ad86e82beed
Mirrors: