DMR11 Synchronous Controller User's Guide

Company:Digital Equipment Corporation
Part:EK-DMR11-UG-002
Date:1980-12
Keywords:PDP-11
Supersedes:

Table of Contents

  • Chapter 1 Introduction
    • 1.1 Scope
    • 1.2 DMR11 General Description
    • 1.3 DMR11 System Operation
      • 1.3.1 Command Structure
      • 1.3.2 Input Commands
      • 1.3.3 Output Commands
      • 1.3.4 DMR11 Operation Sequencing
      • 1.3.5 Maintenance Mode Specification
    • 1.4 General Specifications
      • 1.4.1 Power Requirements
      • 1.4.2 Environmental Requirements -- A11 DMR11s
    • 1.5 EIA Standards Overview (RS-449 vs RS-232-C)
  • Chapter 2 Installation
    • 2.1 Scope
    • 2.2 Unpacking and Inspection
    • 2.3 Installation Considerations
    • 2.4 Preinstallation Considerations
      • 2.4.1 System and Device Placement
        • 2.4.1.1 System Placement
        • 2.4.1.2 Device Placement
      • 2.4.2 System Requirements
    • 2.5 Microprocessor Installation
      • 2.5.1 Backplane Considerations
      • 2.5.2 M8207-RA Considerations
      • 2.5.3 M8207-RA Insertion
    • 2.6 Line Unit Installation
      • 2.6.1 M8203 Considerations
      • 2.6.2 M8203 Insertion
    • 2.7 DMR11 System Testing
      • 2.7.1 Functional Diagnostic Testing
      • 2.7.2 DECX11 System Exerciser
      • 2.7.3 Final Cable Connections
      • 2.7.4 DMR11 Link Testing
    • 2.8 DMR11-XX Installation Check-Off List
  • Chapter 3 Programming
    • 3.1 Introduction
    • 3.2 Command Structure
      • 3.2.1 Control and Status Registers
      • 3.2.2 Initialization
      • 3.2.3 Input Commands Overview
        • 3.2.3.1 Input Command Handshaking
        • 3.2.3.2 Modem Status Read
      • 3.2.4 Output Commands Overview
        • 3.2.4.1 Output Command Handshaking
    • 3.3 Input Commands
      • 3.3.1 Base In
      • 3.3.2 Control In
      • 3.3.3 Receive Buffer Address/Character Count In (RBA/CCI)
      • 3.3.4 Transmit Buffer Address/Character Count In (TBA/CCI)
      • 3.3.5 Halt Request Command
    • 3.4 Output Commands
      • 3.4.1 Receive Buffer Address/Character Count Out (RBA/CCO)
      • 3.4.2 Transmit Buffer Address/Character Count Out (TBA/CCO)
      • 3.4.3 Control Out
    • 3.5 Programming Techniques
      • 3.5.1 Input Command Sequence
      • 3.5.2 Base In Command with Resume Feature
      • 3.5.3 Distinguishing DMR11 from DMC11
      • 3.5.4 DDCMP Maintenance Mode Operation
        • 3.5.4.1 Data Transfer
        • 3.5.4.2 Unattended System Control
    • 3.6 Base Table Counters
    • 3.7 Modem Control
      • 3.7.1 Modem Control Implemented in M8203
        • 3.7.1.1 Modem Ready Lockout of RTS
        • 3.7.1.2 Half-Duplex Mode
      • 3.7.2 Modem Control Implemented in DMR11 Microprogram
        • 3.7.2.1 Auto-Answer
        • 3.7.2.2 Data Set Ready Glitch
        • 3.7.2.3 RTS-CTS Delay
        • 3.7.2.4 Loss of Carrier Detect
        • 3.7.2.5 Receiver Inactive Check
        • 3.7.2.6 Modem Status Read During Input Command
        • 3.7.2.7 Data Terminal Ready Control
    • 3.8 DMR11 Data Link Functions
  • Appendix A Floating Device Addresses and Vectors
    • A.1 Floating Device Addresses
    • A.2 Floating Vector Addresses
    • A.3 Examples of Device and Vector Address Assignment
  • Appendix B DDCMP In a Nutshell
    • B.1 DDCMP
      • B.1.1 Controlling Data Transfers
      • B.1.2 Error Checking and Recovery
      • B.1.3 Character Coding
      • B.1.4 Data Transparency
      • B.1.5 Data Channel Utilization
    • B.2 Protocol Description
    • B.3 Message Format
  • Appendix C Diagnostic Supervisor Summary
    • C.1 Introduction
    • C.2 Versions of the Diagnostic Supervisor
    • C.3 Loading and Running a Supervisor Diagnostic
      • C.3.1 Five Steps to Run a Supervisor Diagnostic
    • C.4 Supervisor Commands
      • C.4.1 Command Switches
      • C.4.2 Control/Escape Characters Supported
    • C.5 What is the Setup Utility?