DUP11 Bit Synchronous Interface Maintenance Manual
Company:
Digital Equipment Corporation
Part:
EK-DUP11-MM-003
Date:
1982-08
Keywords:
Table of Contents
Chapter 1
Introduction
1.1
Scope
1.2
DUP11 General Description
1.3
SDLC and DDCMP Protocols
1.3.1
Introduction
1.3.2
General Information
1.3.3
SDLC Protocol Description
1.3.3.1
Message Format
1.3.3.2
Abort Sequence
1.3.4
DDCMP Protocol
1.3.4.1
Controlling Data Transfers
1.3.4.2
Error Checking and Recovery
1.3.4.3
Character Coding
1.3.4.4
Data Transparency
1.3.4.5
Data Channel Utilization
1.3.4.6
Synchronization
1.3.4.7
Bootstrapping
1.4
Basics of Cycle Redundancy Checking
1.4.1
Mathematical Background
1.4.2
Hardware Implementation of CRC
1.4.3
CRC Operation in DDCMP Protocol
1.4.4
CRC Operation in SDLC Protocol
Chapter 2
Installation
2.1
Scope
2.2
Unpacking and Inspection
2.3
Tools Required for Installation
2.4
Preinstallation Set-Up Procedures
2.5
Installation
2.5.1
M7867 Module Installation
2.5.2
H3001 Distribution Panel Installation
2.5.2.1
H3001 Installation in an I/O Bulkhead
2.5.2.2
H3001 Installation in Cabinets Without an I/O Bulkhead
2.6
Verification of Hardware Operation
2.7
Compatibility
2.8
Power Requirements
2.9
Device Addresses
2.9.1
Introduction
2.9.2
Floating Device Address Assignment
2.9.3
Device Address Selection
2.10
Vector Addresses
2.10.1
Introduction
2.10.2
Floating Vector Address Assignment
2.10.3
Vector Address Selection
Chapter 3
Register Descriptions and Programming Information
3.1
Introduction
3.2
DUP11 Registers and Device Address Selection
3.3
Interrupt Vectors
3.4
Priority Selection
3.5
Register Bit Assignments
3.6
Typical Test Programs
Chapter 4
Theory of Operation
4.1
Introduction
4.2
Functional Description
4.2.1
Logic Description
4.2.1.1
Registers
4.2.1.2
Device Reset Logic
4.2.1.3
Address Selection Logic
4.2.1.4
Unibus Receivers and Drivers
4.2.1.5
Transmitter Logic
4.2.1.6
Receiver Logic
4.2.1.7
CRC Logic
4.2.1.8
Interrupt Control Logic
4.2.1.9
Data Set Interface Logic
4.2.2
Major Operating Features
4.2.2.1
Introduction
4.2.2.2
Modem Control
4.2.2.3
Transmitter Section
4.2.2.4
Receiver Section
4.3
Detailed Description
4.3.1
Introduction
4.3.2
Registers
4.3.2.1
Receiver Control and Status Register (RXCSR)
4.3.2.2
Receiver Data Buffer Register (RXDBUF)
4.3.2.3
Parameter Control and Status Register (PARCSR)
4.3.2.4
Transmitter Control and Status Register (TXCSR)
4.3.2.5
Transmitter Data Buffer Register (TXDBUF)
4.3.3
Device Reset Logic (Logic Sheet BSI1)
4.3.4
Address Selection Logic (Logic Sheet BSI6)
4.3.4.1
Address Assignments and Format
4.3.4.2
Address Decoding
4.3.5
Unibus Registers and Multiplexed Unibus Drivers (Logic Sheet BSI8)
4.3.6
Transmitter Logic (Logic Sheet BSI2)
4.3.6.1
ROMs and Bit Sync Buffer
4.3.6.2
Clock Logic
4.3.6.3
TXDAT Flip-Flop and T1BC Counter
4.3.6.4
Transmitter Character Serialization Counter (TCSC)
4.3.6.5
Transmitter Shift Register
4.3.7
Receiver Logic
4.3.7.1
ROMs and RX Control Flags
4.3.7.2
Clock Logic
4.3.7.3
EN R1BC Flip-Flop and R1BC Counter
4.3.7.4
Character Serialization Counter
4.3.7.5
Receiver Shift Register and Data Buffer
4.3.8
CRC Logic
4.3.8.1
General
4.3.8.2
Error Detection Logic
4.3.8.3
Transmitter CRC Register
4.3.8.4
Receiver CRC Register
4.3.8.5
Typical CRC Accumulation
4.3.9
Interrupt Control Logic
4.3.9.1
General
4.3.9.2
Generation of the Vector Address
4.3.9.3
BR Priority Selector Card
4.3.9.4
Typical Interrupt Transaction
4.3.9.5
NPR Latency Improvement Circuit
4.3.10
Data Set Interface Logic
4.3.10.1
General
4.3.10.2
Logic for Signals from Data Set
4.3.10.3
Logic for Signals to Data Set
4.3.10.4
Logic for Transmitted Data and External Maintenance Clock
4.3.11
Typical Operations
4.3.11.1
Introduction
4.3.11.2
Typical Transmit Operation (SDLC)
4.3.11.3
Typical Receive Operation (SDLC)
Chapter 5
Maintenance
5.1
Scope
5.2
Maintenance Philosophy
5.3
Preventive Maintenance
5.4
Test Equipment Required
5.5
Corrective Maintenance
5.5.1
Maintenance Modes
5.5.1.1
Internal Maintenance
5.5.1.2
System Test
5.5.1.3
External Maintenance
5.5.2
Diagnostic
Appendix A
PDP-11 Memory Organization and Addressing Conventions
Appendix B
Logic Symbology
B.1
Introduction
B.2
Unibus Signal Levels
B.3
Equivalent Gate Symbols
B.4
4-Output Terminal Flip-Flop Symbology
B.5
Redefined 4-Output Terminal Flip-Flops
Appendix C
Integrated Circuit Descriptions
Copies
Address:
http://bitsavers.org/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
Site:
Al Kossow's Bitsavers
Format:
PDF
Size:
11475503 bytes (10.9 MiB)
MD5:
0fe19770d5368082a9d84928bbf3e162
Notes:
As updated by EK-DUP11-MM-CN1, 1983-10
Mirrors:
http://bitsavers.trailing-edge.com/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
http://www.bighole.nl/pub/mirror/www.bitsavers.org/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
http://www.mirrorservice.org/sites/www.bitsavers.org/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
http://bitsavers.informatik.uni-stuttgart.de/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
ftp://bitsavers.informatik.uni-stuttgart.de/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
ftp://ftp.mirrorservice.org/sites/www.bitsavers.org/pdf/dec/unibus/DUP11/EK-DUP11-MM-003_DUP11Maint.pdf
Address:
http://manx-docs.org/collections/hcps/dup11mm3.pdf
Site:
hcps collection
Format:
PDF
Size:
83919593 bytes (80.0 MiB)
MD5:
746f866c81358bfc1fa700c562e191b4
Amended to: