DZ11 Asynchronous Multiplexer Technical Manual

Company:Digital Equipment Corporation
Part:EK-DZ110-TM-002
Date:1978-10
Keywords:

Table of Contents

  • Chapter 1 General Description
    • 1.1 Introduction
    • 1.2 Physical Description
      • 1.2.1 DZ11 Configurations
    • 1.3 General Specifications
      • 1.3.1 Outputs
        • 1.3.1.1 DZ11-A, -B, and -E
        • 1.3.1.2 DZ11-C, -D, and -F
      • 1.3.2 Inputs
      • 1.3.3 Power Requirements, DZ11-A, -B, and -E
      • 1.3.4 Power Requirements, DZ11-C, -D, and -F
      • 1.3.5 Environmental Requirements -- All DZ11s
      • 1.3.6 Distortion -- DZ11-A, -B, and -E
      • 1.3.7 Interrupts
      • 1.3.8 Line Speed
      • 1.3.9 Distance (DZ11-A, -B, and -E)
      • 1.3.10 Distance (DZ11-C, -D, and -F)
    • 1.4 Functional Description
      • 1.4.1 PDP-11 Unibus Interface
      • 1.4.2 Control Logic
      • 1.4.3 Line Interface
  • Chapter 2 Installation
    • 2.1 Scope
    • 2.2 Configuration Differences
    • 2.3 Unpacking and Inspection
    • 2.4 Installation Procedure
      • 2.4.1 H317 Distribution Panel and Static Filter Installation
        • 2.4.1.1 EIA Option
        • 2.4.1.2 20 mA Option
      • 2.4.2 M7819 Module Installation
      • 2.4.3 M7814 Module Installation
  • Chapter 3 Programming
    • 3.1 Introduction
      • 3.1.1 Device and Vector Address Assignments
    • 3.2 Register Bit Assignments
      • 3.2.1 Control and Status Register (CSR)
      • 3.2.2 Receiver Buffer (RBUF)
      • 3.2.3 Line Parameter Register (LPR)
      • 3.2.4 Transmit Control Register (TCR)
      • 3.2.5 Modem Status Register (MSR)
      • 3.2.6 Transmit Data Register (TDR)
    • 3.3 Programming Features
      • 3.3.1 Baud Rate
      • 3.3.2 Character Length
      • 3.3.3 Stop Bits
      • 3.3.4 Parity
      • 3.3.5 Interrupts
      • 3.3.6 Emptying the Silo
      • 3.3.7 Transmitting a Character
      • 3.3.8 Data Set Control
    • 3.4 Programming Examples
  • Chapter 4 Detailed Description
    • 4.1 Scope
    • 4.2 Line-to-Unibus Overall Data Flow (Receive)
    • 4.3 Unibus-to-Line Overall Data Flow (Transmit)
    • 4.4 Functional Block Description
      • 4.4.1 Unibus Interface
        • 4.4.1.1 Address Selection
        • 4.4.1.2 Interrupt Control
        • 4.4.1.3 Data Transceivers and Output Multiplexers
      • 4.4.2 Scanner
      • 4.4.3 Universal Asynchronous Receiver-Transmitter (UART)
    • 4.5 Detailed Functional Description
      • 4.5.1 Address Selection Logic
      • 4.5.2 Receiver Interrupt Logic
      • 4.5.3 Transmitter Interrupt Control
      • 4.5.4 Data Transceivers
      • 4.5.5 Output Multiplexers
      • 4.5.6 Receiver Control Logic
      • 4.5.7 Transmit Control Logic
      • 4.5.8 Registers
        • 4.5.8.1 Control and Status Register
        • 4.5.8.2 Receiver Buffer
        • 4.5.8.3 Line Parameter Register
        • 4.5.8.4 Transmit Control Register
        • 4.5.8.5 Modem Status Register
        • 4.5.8.6 Transmit Data Register
  • Chapter 5 Maintenance
    • 5.1 Maintenance Philosophy
    • 5.2 Preventive Maintenance
    • 5.3 Test Equipment Required
    • 5.4 DZ11 Maintenance Software
    • 5.5 Corrective Maintenance
      • 5.5.1 Internal Loopback Mode
      • 5.5.2 Staggered Loopback Mode
      • 5.5.3 External Mode
      • 5.5.4 On-Line with Terminal
  • Appendix A DZ11 (M7814) to an Active Device Installation
  • Appendix B Universal Asynchronous Receiver/Transmitter (UART)
  • Appendix C Dual Baud Rate Generator (COM5016)
  • Appendix D Integrated Circuits

Copies

Address: http://bitsavers.org/pdf/dec/unibus/DZ11_TechnicalMan.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 5388532 bytes (5.1 MiB)
MD5: 32df995d759f92dea811e1e5793a1c8e
Mirrors:
 
Address: http://bitsavers.org/pdf/dec/unibus/DZ11Prog.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 1480205 bytes (1.4 MiB)
MD5: 9b3c2b3a3f589a2971b1d32b770ec01d
Notes: Chapter 3 only (Programming information)
Mirrors: