RT-11 System Generation Guide

Company:Digital Equipment Corporation
Part:AA-M240B-TC
Date:1984-07
Keywords:
Operating System:RT-11 Version 5.1

Table of Contents

  • Chapter 1 Preparing for System Generation
    • 1.1 System Generation Process
    • 1.2 Gathering Information
      • 1.2.1 Peripheral Devices
      • 1.2.2 Interrupt Vectors and CSRs
      • 1.2.3 Monitor Services for Target Application
      • 1.2.4 Defining Other System Conditionals
      • 1.2.5 System Build Procedure
        • 1.2.5.1 Automatic System Build
        • 1.2.5.2 Manual System Build
    • 1.3 Studying the SYSGEN Dialog
  • Chapter 2 Performing the System Generation Process on a Disk System
    • 2.1 Running the Program IND.SAV
    • 2.2 Collecting the Appropriate Files on the Appropriate Media
    • 2.3 Assembling and Linking the Monitor(s) and Device Handlers
      • 2.3.1 Using SYSGEN.BLD to Build the System
      • 2.3.2 Using SYSGEN.MON and SYSGEN.DEV to Build the System
      • 2.3.3 Building Handlers Separately
  • Chapter 3 Performing the System Generation Process on a Small System
    • 3.1 Creating a Working System for This Process
    • 3.2 Running the Program SYSGEN.COM
    • 3.3 Collecting the Appropriate Files on the Diskettes
      • 3.3.1 System Build Indirect Command Files
      • 3.3.2 Creating System Build Diskettes
        • 3.3.2.1 Diskette Contents
        • 3.3.2.2 Copying the Files
    • 3.4 Assembling and Linking the Monitor(s) and Device Handlers
      • 3.4.1 Assembling Files
      • 3.4.2 Linking Files
  • Appendix A SYSGEN Answers That Will Duplicate the Standard Monitors
    • A.1 SJ and FB Monitors
    • A.2 XM Monitor
    • A.3 SYSGEN Questions
  • Appendix B SYSGEN Answers That Create a Multiterminal System
  • Appendix C RT-11 Conditionals
    • C.1 System Conditionals
      • C.1.1 SJ.MAC
      • C.1.2 FB.MAC
      • C.1.3 XM.MAC
    • C.2 Individual Keyboard Monitor Command Conditionals
    • C.3 Naming-Convention Conditionals
  • Appendix D Customizations for Specially Generated Monitors
    • D.1 Installing Only the Generated Handlers
    • D.2 Suppressing the Multiterminal Polling Routines
    • D.3 Changing the Handler File-Name Suffix
    • D.4 Changing the Default Device for the SRUN Command
    • D.5 Changing the Default File Type for the SRUN Command
    • D.6 Assigning a Remote Line as the Console Terminal
    • D.7 Changing the Device Name of the UCL File

Copies

Address: http://vt100.net/dec/aa-m240b-tc.pdf
Site: Paul Williams' VT100.net
Format: PDF
Size: 4673521 bytes (4.5 MiB)
MD5: a54ae71e261d232c30c0dbb0cda60be7
Mirrors:
 
Address: http://www.computer.museum.uq.edu.au/RT-11/AA-M240B-TC%20RT-11%20System%20Generation%20Guide.pdf
Site: Wilber Williams' Computer Museum
Format: PDF
Size: 8799581 bytes (8.4 MiB)
MD5: 521f5039aed76f93c8b383cbcfd31287
Mirrors: