RT100/102/137 Video Terminals Pocket Service Guide

Company:Digital Equipment Corporation
Part:EK-RT100-PS-001
Date:1982-09
Keywords:RT102, RT137, ruggedized, ruggedised

Table of Contents

  • 1 Testing and Troubleshooting
    • 1.1 Introduction
    • 1.2 Prechecks
    • 1.3 Self-Tests
      • 1.3.1 Error Codes
      • 1.3.2 Power-Up Test
      • 1.3.3 Data Loopback Test
      • 1.3.4 EIA Test
      • 1.3.5 Printer Port EIA Test (RT102 Only)
      • 1.3.6 Video Alignment Pattern
      • 1.3.7 SET-UP Screen Test
    • 1.4 Troubleshooting Checks
    • 1.5 Checklist
  • 2 Removal and Replacement
    • 2.1 Introduction
    • 2.2 Access Cover
    • 2.3 Terminal Controller Board
    • 2.4 Advanced Video Board
    • 2.5 Standard Terminal Port
    • 2.6 RT137 Bar Code Module
    • 2.7 20 mA Current Loop Board
    • 2.8 Membrane Keyboard
    • 2.9 Terminal Top Cover
    • 2.10 Video Monitor Board (RT100 and RT137)
    • 2.11 Video Monitor Board (RT102)
    • 2.12 Flyback Transformer and Vertical Choke (RT100 and RT137)
    • 2.13 Flyback Transformer and Vertical Choke (RT102)
    • 2.14 Terminal Base Assembly
    • 2.15 Fans
    • 2.16 Chassis Bottom Cover
    • 2.17 Power Supply (RT100 and RT137)
    • 2.18 Power Supply (RT102)
    • 2.19 RT102 Power Supply Transformer
    • 2.20 RT100 DC Power Harness
    • 2.21 RT137 Expansion Backplane
    • 2.22 CRT and Yoke Assembly
    • 2.23 CRT Storage
    • 2.24 CRT Disposal
  • 3 Video Alignment
    • 3.1 Introduction
    • 3.2 Monitor Adjustments
      • 3.2.1 Brightness Adjustment
      • 3.2.2 Focus Adjustment
      • 3.2.3 Yoke Adjustment
      • 3.2.4 Vertical Height Adjustment
      • 3.2.5 Vertical Linearity Adjustment
      • 3.2.6 Horizontal Width Adjustment
      • 3.2.7 Centering Adjustment
  • 4 Operating Summary
    • 4.1 SET-UP Mode
      • 4.1.1 SET-UP A
      • 4.1.2 SET-UP B (RT100 and RT137)
      • 4.1.3 SET-UP B (RT102)
      • 4.1.4 Changing SET-UP Features
      • 4.1.5 Setting the Answerback Message
      • 4.1.6 Saving SET-UP Features
      • 4.1.7 Recalling SET-UP Features
      • 4.1.8 Resetting the Terminal
  • 5 Board Configurations
    • 5.1 General
    • 5.2 RT100 Board Configurations
    • 5.3 RT102 Board Configurations
    • 5.4 RT137 Bar Code Module Switch Configuration
  • 6 Options
    • 6.1 General
    • 6.2 RT100 Options
    • 6.3 RT102 Options
    • 6.4 RT137 Options
  • 7 Maintenance
    • 7.1 Maintenance Philosophy
    • 7.2 Special Tools Required
    • 7.3 Recommended Weekly Customer Preventive Maintenance
    • 7.4 Field Service Normal Maintenance Procedure
  • 8 Field Replaceable Units

Copies