UDA50 Service Manual

Company:Digital Equipment Corporation
Part:EK-UDA50-SV-003
Date:1984-08
Keywords:disk controller

Table of Contents

  • Chapter 1 Introduction
    • 1.1 Scope of Manual
    • 1.2 UDA50 Maintenance Philosophy
    • 1.3 UDA50 Field Replaceable Parts
    • 1.4 UDA50 Maintenance Features
    • 1.5 UDA50 Address Switches and Jumpers
      • 1.5.1 UNIBUS Tuning
    • 1.6 UDA50 Priority Plug
    • 1.7 Installation of Bootstrap ROM
    • 1.8 Related Documentation
  • Chapter 2 UDA50 Fault Isolation
    • 2.1 UDA50-Resident Diagnostics
      • 2.1.1 UDA50 LED Error Codes
      • 2.1.2 Status/Address Register Error Codes
    • 2.2 Host-Resident Diagnostics
      • 2.2.1 PDP-11 Subsystem Diagnostics Preparation
      • 2.2.2 VAX Subsystem Diagnostics Preparation
    • 2.3 Running the Host-Resident Diagnostics
    • 2.4 Interpreting Host-Resident Diagnostic Messages
      • 2.4.1 Status/Address (SA) Register Contents
      • 2.4.2 Data Comparison Errors
      • 2.4.3 Real-Time Drive State and Status
      • 2.4.4 Status Message Bytes
      • 2.4.5 Status Message Interpretation
    • 2.5 Subsystem Error Messages
    • 2.6 Host Error Log Examination
    • 2.7 Common Error Log Message Definitions
    • 2.8 Decoding VMS Error Log Reports
      • 2.8.1 Sample Printout Of VMS Error Report Sequence 1
      • 2.8.2 Notes For VMS Error Report Sequence 1
      • 2.8.3 Sample Printout Of VMS Error Report Sequence 2
      • 2.8.4 Notes for VMS Error Report Sequence 2
    • 2.9 Decoding RSTS/E Error Logs
      • 2.9.1 Sample Printout of RSTS/E Error Log Report
      • 2.9.2 Notes For RSTS/E Error Log Report
      • 2.9.3 Decoding MSCP Packet Message Format
      • 2.9.4 Recovering Error Information in MSCP Packet
      • 2.9.5 Status Word Availability
      • 2.9.6 Decode Status Words
    • 2.10 Decoding RSX Error Logs
      • 2.10.1 Sample Printout of RSX-11 Error Log Report (SDI Error Format)
      • 2.10.2 Notes for RSX-11 Error Log Report (SDI Error Format)
      • 2.10.3 Sample Printout of RSX-11 Error Log Report (Disk Transfer Format)
      • 2.10.4 Notes for RSX-11 Error Log Report (Disk Transfer Error Format)
      • 2.10.5 Remaining Error Log Packet Formats
    • 2.11 Introduction to SPEAR
      • 2.11.1 Faulty FRU Selection
      • 2.11.2 Replace the FRU Suggested By SPEAR
    • 2.12 Summary
  • Appendix A Tables

Copies

Address: http://bitsavers.org/pdf/dec/disc/uda50/EK-UDA50-SV-003_serviceMan.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 3651231 bytes (3.5 MiB)
MD5: 37e10bd2e8da6bd96eb3a72feeea56ee
Mirrors: