PDP-11/44 System Technical Manual

Company:Digital Equipment Corporation
Part:EK-KD11Z-TM-001
Date:1980-12
Keywords:H7104

Table of Contents

  • Chapter 1 Introduction
    • 1.1 General
    • 1.2 Equipment Description
      • 1.2.1 PDP-11/44 CA, -CB Processor System
      • 1.2.2 PDP-11X44 Processor System
      • 1.2.3 Standard Hardware Components
      • 1.2.4 Hardware Options
    • 1.3 Equipment Specifications
      • 1.3.1 PDP-11/44 System Specifications
      • 1.3.2 PDP-11X44 System Specifications
      • 1.3.3 H7140 AA, -AB Power Supply Electrical Specifications
    • 1.4 System Description
      • 1.4.1 KD11-Z Central Processor
        • 1.4.1.1 Data Path Module (M7094)
        • 1.4.1.2 Control Module (M7095)
        • 1.4.1.3 Multifunction Module (M7096)
        • 1.4.1.4 UNIBUS Interface Module (M7098)
        • 1.4.1.5 Console Interface Module (M7090)
      • 1.4.2 MOS Memory
      • 1.4.3 KK11-B Cache Memory
      • 1.4.4 UNIBUS Terminator (M9302)
      • 1.4.5 Optional Modules and Devices
        • 1.4.5.1 FP11-F Floating-Point Processor
        • 1.4.5.2 KE44-A Commercial Instruction Set Processor
        • 1.4.5.3 TU58 DECtape II
        • 1.4.5.4 Standard PDP-11 Peripheral Devices
    • 1.5 Related Documents
      • 1.5.1 DIGITAL Personnel Ordering
      • 1.5.2 Customer Ordering Information
  • Chapter 2 Operation
    • 2.1 Front Control Panel
    • 2.2 Console Commands
      • 2.2.1 Special Functions
        • 2.2.1.1 Console Command Qualifiers
        • 2.2.1.2 Special Address Field Characters
        • 2.2.1.3 Control Characters
      • 2.2.2 ADDER Command
      • 2.2.3 BOOT Command
      • 2.2.4 CONTINUE Command
      • 2.2.5 DEPOSIT Command
      • 2.2.6 EXAMINE Command
      • 2.2.7 FILL Command
      • 2.2.8 HALT Command
      • 2.2.9 INITIALIZE Command
      • 2.2.10 MICROSTEP Command
      • 2.2.11 SINGLE-INSTRUCTION-STEP Command
      • 2.2.12 START Command
      • 2.2.13 SELF-TEST Command
      • 2.2.14 BINARY LOAD/UNLOAD Command
      • 2.2.15 REPEAT Command
      • 2.2.16 Summary of Errors
      • 2.2.17 Summary of Commands
    • 2.3 PDP-11/44 Registers
      • 2.3.1 CPU Registers
        • 2.3.1.1 Processor Status Word
        • 2.3.1.2 Program Interrupt Request Register
        • 2.3.1.3 Error Register
        • 2.3.1.4 General Registers
      • 2.3.2 Multifunction Module Register
        • 2.3.2.1 Console Terminal Receiver Control/Status Register
        • 2.3.2.2 Console Terminal Receiver Data Buffer Register
        • 2.3.2.3 Console Terminal Transmitter Control/Status Register
        • 2.3.2.4 Console Terminal Transmitter Buffer Register
        • 2.3.2.5 TU58 Receiver Control/Status Register
        • 2.3.2.6 TU58 Receiver Buffer Register
        • 2.3.2.7 TU58 Transmitter Control/Status Register
        • 2.3.2.8 TU58 Transmitter Data Buffer Register
        • 2.3.2.9 Signal Register
        • 2.3.2.10 Line Time Clock Control/Status Register
      • 2.3.3 Cache Memory I/O Page Registers
        • 2.3.3.1 Cache Memory Data Register
        • 2.3.3.2 Cache Hit Register
        • 2.3.3.3 Cache Maintenance Register
        • 2.3.3.4 Cache Control/Status Register
        • 2.3.3.5 Cache Error Register
      • 2.3.4 Memory Management Registers
        • 2.3.4.1 Status Register 0 (SR0)
        • 2.3.4.2 Status Register SR1
        • 2.3.4.3 Status Register SR2
        • 2.3.4.4 Status Register SR3
        • 2.3.4.5 Page Address Registers
        • 2.3.4.6 Page Description Register
  • Chapter 3 CPU Configuration
    • 3.1 Processor Backplane Assignments
      • 3.1.1 Backplane Assembly Pin Designations
      • 3.1.2 Module Contact Designations
      • 3.1.3 SPC Module Installation
    • 3.2 Module Current Requirements
      • 3.2.1 DC Power Requirements
      • 3.2.2 H7140-AA, -AB DC Power Outputs
    • 3.3 Module Switches, Jumpers and Indicators
      • 3.3.1 Console Interface Module (M7090)
        • 3.3.1.1 Console Terminal Configurations
        • 3.3.1.2 TU58 DECtape II Configuration
        • 3.3.1.3 Remote Diagnosis Configuration
        • 3.3.1.4 Voltage Monitoring
        • 3.3.1.5 LED Indicator
      • 3.3.2 Multifunction Module (M7096)
        • 3.3.2.1 Console Terminal Jumper Leads Selections
        • 3.3.2.2 MFM Console Terminal Baud Rate Selection
        • 3.3.2.3 MFM TU58 DECtape II Jumper Leads
        • 3.3.2.4 MFM TU58 Baud Rate Selection
        • 3.3.2.5 MFM TU58 Device Address Selection
        • 3.3.2.6 TU58 Vector Address Selection
        • 3.3.2.7 Line Time Clock Enable/Disable
      • 3.3.3 UNIBUS Interface Module (M7098)
        • 3.3.3.1 UBI Jumper Leads and Memory Page Selection
        • 3.3.3.2 Diagnostic and Bootstrap Loader ROMs
      • 3.3.4 Cache Memory Module (M7097)
        • 3.3.4.1 LED Indicator Functions
        • 3.3.4.2 Multiport Memory Selection
      • 3.3.5 Control Module (M7095)
  • Chapter 4 Installation
    • 4.1 Site Considerations
      • 4.1.1 Temperature and Humidity
      • 4.1.2 Acoustical Dampening
      • 4.1.3 Lighting
      • 4.1.4 Static Electricity
      • 4.1.5 Shock and Vibration
      • 4.1.6 Electrical Interface
    • 4.2 Unpacking
      • 4.2.1 PDP-11/44-CA, -CB Unit Removal
      • 4.2.2 PDP-11X44-CA, -CB Cabinet Removal
        • 4.2.2.1 Shipping Restraint Removal
    • 4.3 Equipment Dimensions
    • 4.4 AC Input Power Requirements
      • 4.4.1 Power Connections (AC)
      • 4.4.2 System Grounding
    • 4.5 PDP-11/44 Mounting Box Installation
      • 4.5.1 Index Plate Mounting
      • 4.5.2 Slide Assembly Mounting
      • 4.5.3 Mounting Box to Slide Installation
    • 4.6 PDP-11X44 System Cabinet Installation
      • 4.6.1 Base Stabilizer Installation
      • 4.6.2 Servicing Area
    • 4.7 Cable Routing
      • 4.7.1 Mounting Box Cable Routing
      • 4.7.2 PDP-11X44 Cabinet Cable Routing
    • 4.8 Power Checks
      • 4.8.1 AC Power Distribution
        • 4.8.1.1 Initial AC Power Checks
      • 4.8.2 DC Power Distribution
        • 4.8.2.1 DC Power Checks
    • 4.9 Performance Evaluation
      • 4.9.1 MAINDEC Diagnostic Programs
        • 4.9.1.1 Diagnostic Designations
      • 4.9.2 Internal Diagnostic Programs
  • Chapter 5 Removal/Replacement Procedures
    • 5.1 BA11-AA, -AB Mounting Box in System Cabinet
      • 5.1.1 Mounting Box Removal
      • 5.1.2 Interface Bracket Removal/Installation
      • 5.1.3 Mounting Box Replacement
    • 5.2 BA11-AA, -AB Slide Mounted Removal/Replacement
    • 5.3 Fan Assembly
      • 5.3.1 Fan Assembly Removal/Replacement
    • 5.4 H7140-AA, -AB Power Supply Removal/Replacement
      • 5.4.1 Power Supply Removal
      • 5.4.2 Power Supply Replacement
    • 5.5 Optional Backplane Assemblies
      • 5.5.1 Optional Backplane Configurations
      • 5.5.2 Backplane Assembly Installation
      • 5.5.3 Backplane Connector Assignments
      • 5.5.4 NPG and BG Jumper Lead Routing
      • 5.5.5 Standard and Modified Backplane Locations
      • 5.5.6 SPC Backplane Locations
      • 5.5.7 Backplane Power Connections
  • Chapter 6 Detailed Functional Description
    • 6.1 Introduction
    • 6.2 Control Store
      • 6.2.1 MicroPC Generation
    • 6.3 Data Path
      • 6.3.1 Arithmetic Logic Unit (ALU)
      • 6.3.2 ALU B-Reg Logic
      • 6.3.3 ALU Multiplexer (AMUX)
      • 6.3.4 Swap Sign Extend Multiplexer (SSMUX)
      • 6.3.5 Scratchpad Memory
        • 6.3.5.1 Scratchpad Operation
      • 6.3.6 Processor Status Word (PSW)
    • 6.4 Instruction Decode
      • 6.4.1 Instruction Classes
        • 6.4.1.1 Double Operand and Branch Instructions
        • 6.4.1.2 Single Operand Instructions
        • 6.4.1.3 Miscellaneous Instructions
      • 6.4.2 Miscellaneous Decoding for Reset Instruction and T Bit
      • 6.4.3 ALU Auxiliary Control
    • 6.5 Data Transfer Logic
      • 6.5.1 UNIBUS Transfer Logic
        • 6.5.1.1 Processor Clock Inhibit
        • 6.5.1.2 UNIBUS Synchronization
        • 6.5.1.3 Bus Control
        • 6.5.1.4 Generation of MSYN and MSYN/SSYN Timeout
        • 6.5.1.5 Restarting Processor Clock
      • 6.5.2 Bus Arbitration
        • 6.5.2.1 Bus Requests
        • 6.5.2.2 Request Synchronization
        • 6.5.2.3 SACK Timeout
        • 6.5.2.4 Programmed Interrupt Request (PIRQ)
      • 6.5.3 Error Logic
      • 6.5.4 Cache Interface
    • 6.6 System Clock
    • 6.7 Power Fail/Auto Restart
    • 6.8 Memory Management
      • 6.8.1 Relocation
        • 6.8.1.1 Address Mapping
        • 6.8.1.2 Address Translation
      • 6.8.2 Protection
      • 6.8.3 Page Address Registers (PAR)
      • 6.8.4 Page Descriptor Registers (PDR)
      • 6.8.5 Memory Management Fault Logic
      • 6.8.6 I and D Space
    • 6.9 UNIBUS Map
      • 6.9.1 Map Control
      • 6.9.2 Map Addressing and Relocation
      • 6.9.3 Addressing Limits
    • 6.10 Console Processor
      • 6.10.1 8085 Addressing
      • 6.10.2 Console Data Flow
      • 6.10.3 Console-to-VAX Interface
      • 6.10.4 Operation During Command Execution
    • 6.11 Serial Line Units
      • 6.11.1 Console Terminal SLU
        • 6.11.1.1 Transmitter Operation (Terminal UART)
        • 6.11.1.2 Receiver Operation (Terminal UART)
        • 6.11.1.3 Console Terminal Baud Rate Logic
      • 6.11.2 TU58 SLU
        • 6.11.2.1 Transmitter Operation (TU58 UART)
        • 6.11.2.2 Receiver Operation (TU58 UART)
        • 6.11.2.3 Baud Rate Logic
      • 6.11.3 Address Selection
      • 6.11.4 Console Terminal and TU58 Register Descriptions
        • 6.11.4.1 Terminal Receiver Status Register
        • 6.11.4.2 Terminal Receiver Buffer Register
        • 6.11.4.3 Terminal Transmitter Status Register
        • 6.11.4.4 Terminal Transmitter Buffer Register
        • 6.11.4.5 Line Clock Status Register
        • 6.11.4.6 TU58 Receiver Status Register
        • 6.11.4.7 TU58 Receiver Buffer Register
        • 6.11.4.8 TU58 Transmitter Status Register
        • 6.11.4.9 TU58 Transmitter Buffer Register
      • 6.11.5 Interrupt Request Logic
        • 6.11.5.1 Arbitration Between Terminal and TU58 Interrupts
    • 6.12 KK11-B Cache
      • 6.12.1 Memory Organization
      • 6.12.2 Interface Logic
      • 6.12.3 Address Logic
      • 6.12.4 Data Control
        • 6.12.4.1 Write Data Latching
        • 6.12.4.2 Read Data Enable
      • 6.12.5 Cache Array
        • 6.12.5.1 Data Section
        • 6.12.5.2 Tag Section
      • 6.12.6 Cache Flush Control
      • 6.12.7 Valid Control Logic
      • 6.12.8 Write Control Logic
      • 6.12.9 Hit Detect Logic
      • 6.12.10 Cache Register Logic
      • 6.12.11 Address Match Logic
      • 6.12.12 Cache Registers

Copies

Address: http://bitsavers.org/pdf/dec/pdp11/1144/1144_SystemTechMan.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 13668782 bytes (13.0 MiB)
MD5: 4eb8609821ef2093ff6ffd43e012279a
Mirrors: