Guest |
Login
version 2.1.0
Manx – a catalogue of online computer manuals
Search
News
About
Help
QMA DMV11 Synchronous Controller User's Guide
Company:
Digital Equipment Corporation
Part:
EK-DMVQM-UG-003
Date:
1988-08
Keywords:
Supersedes:
EK-DMVQM-UG-002,
QMA DMV11 Synchronous Controller User's Guide
Table of Contents
Chapter 1
Introduction
1.1
Introduction
1.2
Introduction to Multipoint
1.3
DMV11 General Description
1.4
Standard Applications
1.5
DMV11 System Operation
1.6
Command/Response Structures
1.6.1
Input Commands
1.6.2
Output Responses
1.7
Protocol Support
1.7.1
Data Messages
1.7.2
Control Messages
1.7.3
Maintenance Messages
1.8
General Specifications
1.8.1
Environmental Specifications
1.8.2
Electrical Specifications
1.8.3
Performance Specifications
Chapter 2
Installation
2.1
Introduction
2.2
Unpacking and Inspection
2.3
Installation Considerations
2.4
Preinstallation Considerations
2.4.1
Device Placement
2.4.2
System Requirements
2.5
Installation
2.6
DMV11 System Testing
2.6.1
Functional Diagnostic Testing
2.6.2
DEC/X11 System Exerciser
2.6.3
Final Cable Connections
2.6.4
DMV11 Link Testing
2.6.5
MDM Diagnostics
2.7
DMV11-SF Synchronous Interface Option
2.7.1
BA200 Series System Enclosures
2.7.2
Module Differences
2.8
Installation
2.8.1
Unpacking the Option Kit
2.8.2
Inspecting the FCC and EOS Clips
2.8.3
Software Backup
2.8.4
Configuration
2.8.5
Checking the System Configuration
2.8.6
Guidelines for Module Placement
2.8.6.1
Bus Continuity
2.8.6.2
Power Supplies
2.8.6.3
DMV11-SA Bus Priority
2.8.7
Finding CSR Addresses and Interrupt Vectors
2.8.7.1
MicroPDP-11 Systems
2.8.7.2
MicroVAX Systems
2.8.8
Configuring the DMV11-SF Option
2.9
Operating System Software Shutdown
2.10
Testing the System
2.11
Relocating Existing Modules
2.11.1
Modules with Handles
2.11.2
Modules with Blank Covers
2.12
Verifying the Ground Connections
2.13
Installing the DMV11 Module
2.14
Connecting External Devices
Chapter 3
Command and Response Structures
3.1
Introduction
3.2
Command Structure
3.2.1
Control and Status Registers
3.2.2
Input Commands Overview
3.2.3
Output Responses Overview
3.3
DMV11 Input Commands
3.3.1
Microprocessor Control/Maintenance Command
3.3.2
Mode Definition Command
3.3.3
Control Command
3.3.4
Buffer Address/Character Count (BA/CC) Command
3.4
DMV11 Output Responses
3.4.1
Buffer Disposition Response
3.4.2
Control Response
3.4.3
Information Response
3.5
TSS/GSS Access
Chapter 4
Programming Techniques
4.1
Introduction
4.2
Command/Response Discipline and Handshaking
4.2.1
Command Discipline
4.2.2
Retrieving Responses
4.2.3
CSR Interface Interactions
4.3
DMV11 Start-Up
4.3.1
Configuration Procedure
4.3.2
Specifying User-Defined Parameters
4.3.2.1
Specifying TSS Parameters
4.3.2.2
Specifying GSS Parameters
4.3.3
Protocol Operation
4.4
Criteria for Determining Communications Link Parameters
4.4.1
Setting the Selection Interval Timer
4.4.2
Setting the Babbling Tributary Timer
4.4.3
Setting the Streaming Tributary Timer
4.5
Error Counter Access
4.5.1
Reading the Counters
4.5.2
Counter Skew
4.6
Error Recovery Procedures
4.6.1
Recovery from Network Errors
4.6.1.1
Recovery from Threshold Errors
4.6.1.2
Recovery from Babbling and Streaming Tributary Errors
4.6.2
Recovery from Procedural Errors
4.6.2.1
Recovery from a Nonexistent Memory Error
4.6.2.2
Recovery from a Receive Buffer Too Small Error
4.6.2.3
Recovery from a Queue Overflow Error
4.7
Booting a Remote Station
4.7.1
Steps Leading to a Remote Load Detect Boot
4.7.2
Steps Leading to a Power-On Boot
4.7.3
Steps Leading to an Invoke Primary MOP Boot
4.7.4
DMV11 Switch Settings for the Boot Functions
4.7.4.1
Switch Settings for the Power-On Boot Function
4.7.4.2
Switch Settings for the Invoke Primary MOP Boot Function
4.7.4.3
Switch Settings for the Remote Load Detect Boot Function
4.8
Maintenance Register Emulation
Chapter 5
Aspects of DMV11 Microcode Operation
5.1
Introduction
5.2
DMV11 Polling Algorithm
5.2.1
Calculating Polling Urgency
5.2.2
Criteria for Determining Polling Parameters
5.2.2.1
Determining a Value for DELTA T
5.2.2.2
Determining Values for Q and R
5.2.2.3
Determining a Value for Poll Delay
5.2.2.4
Determining a Value for DEAD T
5.3
Error Counters
5.3.1
Data Link Error Counters
5.3.1.1
Data Errors Outbound
5.3.1.2
Data Errors Inbound
5.3.1.3
Local Reply Timeouts
5.3.1.4
Remote Reply Timeouts
5.3.1.5
Local Buffer Errors
5.3.1.6
Remote Buffer Errors
5.3.1.7
Selection Timeouts
5.3.1.8
Data Messages Transmitted
5.3.1.9
Data Messages Received
5.3.1.10
Selection Intervals
5.3.2
Station Error Counters
5.3.2.1
Remote Station Errors
5.3.2.2
Local Station Errors
5.3.2.3
Global Header Block-Check Errors
5.3.2.4
Maintenance Data Field Block-Check Errors
5.3.3
Threshold Error Counters
5.3.3.1
Transmit Threshold Errors
5.3.3.2
Receive Threshold Errors
5.3.3.3
Selection Threshold Errors
5.4
DMV11 Microcode Internal Data Base Overview
5.4.1
Linked Lists
5.4.1.1
The Free Linked List
5.4.1.2
The Response Linked List
5.4.1.3
Buffer Linked Lists
5.4.2
Slot Mapping Table
5.4.3
TSS and GSS Structures
5.4.3.1
The Global Status Slot (GSS)
5.4.3.2
Tributary Status Slots (TSS)
Appendix A
DDCMP
A.1
DDCMP
A.1.1
Controlling Data Transfers
A.1.2
Error Checking and Recovery
A.1.3
Character Coding
A.1.4
Data Transparency
A.1.5
Data Channel Utilization
A.2
Protocol Description
A.3
Message Format
Appendix B
Floating Device CSR and Interrupt Vector Addresses
B.1
Floating Device CSR Addresses
B.2
Floating Interrupt Vector Addresses
B.3
Examples of Device CSR and Interrupt Vector Address Assignment
Appendix C
Modem Control Register Formats
C.1
Modem Control Register Formats
C.2
RS-449 Versus RS-232-C
Appendix D
Modem Control
D.1
Modem Control
D.1.1
Hardware Modem Control
D.1.2
Modem Control Implemented by the DMV11 Microcode
Appendix E
QMA DMV11 Option Configurations
E.1
Introduction
E.2
Option Designation Conversion
E.2.1
Installed Option
E.2.2
Add-On Option
E.2.2.1
Base Options
E.2.2.2
Cabinet Kits
E.3
Option Configuration Summary
E.3.1
Base Option Designations
E.3.2
Cabinet Kit Designations
E.4
DMV11 Option Configurations
Copies
Address:
http://bitsavers.org/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
Site:
Al Kossow's Bitsavers
Format:
PDF
Size:
7745386 bytes (7.4 MiB)
Amended to:
Mirrors:
http://bitsavers.trailing-edge.com/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
http://www.bighole.nl/pub/mirror/www.bitsavers.org/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
http://www.mirrorservice.org/sites/www.bitsavers.org/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
http://bitsavers.informatik.uni-stuttgart.de/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
ftp://bitsavers.informatik.uni-stuttgart.de/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
ftp://ftp.mirrorservice.org/sites/www.bitsavers.org/pdf/dec/qbus/DMV11/EK-DMVQM-UG-003_Aug88.pdf
Address:
http://bitsavers.org/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf
Site:
Al Kossow's Bitsavers
Format:
PDF
Size:
9333087 bytes (8.9 MiB)
MD5:
611d8e46abea13c151ddce19ba7ebdde
Mirrors:
http://bitsavers.trailing-edge.com/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf
http://www.bighole.nl/pub/mirror/www.bitsavers.org/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf
http://www.mirrorservice.org/sites/www.bitsavers.org/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf
http://bitsavers.informatik.uni-stuttgart.de/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf
ftp://bitsavers.informatik.uni-stuttgart.de/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf
ftp://ftp.mirrorservice.org/sites/www.bitsavers.org/pdf/dec/qbus/EK-DMVQM-UG-003_Aug88.pdf