NIA20 Technical Reference Manual

Company:Digital Equipment Corporation
Part:EK-NIA20-RM-001
Date:1985-01
Keywords:

Table of Contents

  • Chapter 1 Introduction
    • 1.1 NIA20 Subsystem Overview
      • 1.1.1 Network Interconnect Adapter Module
      • 1.1.2 Port
        • 1.1.2.1 EBus Interface/port ALU Module (M3001)
        • 1.1.2.2 Port Microprocessor Control Module (M3002)
        • 1.1.2.3 CBus-PLI Interface Module (M3003)
      • 1.1.3 H4000 Transceiver
        • 1.1.3.1 Transmit Function
        • 1.1.3.2 Watchdog Timer Function
        • 1.1.3.3 Collision Presence Function
        • 1.1.3.4 Collision Presence Test Function (Heartbeat)
        • 1.1.3.5 Receive Function
        • 1.1.3.6 DC To DC Converter
        • 1.1.3.7 Coaxial Cable Connection
        • 1.1.3.8 Transceiver Cable Connections
    • 1.2 Ethernet Specification Overview
      • 1.2.1 Packet Format
        • 1.2.1.1 Maximum Packet Size
        • 1.2.1.2 Minimum Packet Size
        • 1.2.1.3 Preamble
        • 1.2.1.4 Destination Address
        • 1.2.1.5 Source Address
        • 1.2.1.6 Type Field
        • 1.2.1.7 Data Field
        • 1.2.1.8 Packet Check Sequence
        • 1.2.1.9 Round-Trip Delay
      • 1.2.2 Control Procedures
        • 1.2.2.1 Defer
        • 1.2.2.2 Transmit
        • 1.2.2.3 Abort
        • 1.2.2.4 Retransmit
        • 1.2.2.5 Backoff
      • 1.2.3 Manchester Encoding
      • 1.2.4 Carrier Sense
      • 1.2.5 Transceiver Connections
      • 1.2.6 Transceivers
  • Chapter 2 Implementation
    • 2.1 Implementation Overview
    • 2.2 Queue Structure
      • 2.2.1 Queue Linkage
      • 2.2.2 Queue Interlocks
      • 2.2.3 Queue Locations
    • 2.3 Queue Handling
      • 2.3.1 Queue Headers
      • 2.3.2 Entry Linking
      • 2.3.3 Entry Removal
        • 2.3.3.1 Buffer Segment Descriptors
        • 2.3.3.2 Buffer Segment Descriptor Format
    • 2.4 Commands and Responses
      • 2.4.1 Command and Response Formats
        • 2.4.1.1 Send Datagram (SNDDG) Command
        • 2.4.1.2 Datagram Sent (DGSNT) Response
        • 2.4.1.3 Datagram Received (DGRCV) Response
        • 2.4.1.4 Load Protocol Type Table (LDPTT) Command
        • 2.4.1.5 Protocol Type Table Loaded (PTTLD) Response
        • 2.4.1.6 Load Multicast Address Table (LDMCAT) Command
        • 2.4.1.7 MCAT Loaded Response LDMCAT
        • 2.4.1.8 Read and Clear Performance Counters RCCNT Command
        • 2.4.1.9 Counters Read or Cleared (CNTRC) Response
        • 2.4.1.10 Write Port Link Interface (WRTPLI) Command
        • 2.4.1.11 Port Link Interface Written (PLIWRT) Response
        • 2.4.1.12 Read Port Link Interface (RDPLI) Command
        • 2.4.1.13 Port Link Interface Read (PLIRD) Response
        • 2.4.1.14 Read NI Station Address (RDNSA) Command
        • 2.4.1.15 NI Station Address Read (NSARD) Response
        • 2.4.1.16 Write NI Station Address (WRTNSA) Command
        • 2.4.1.17 NI Station Address Written (NSAWRT) Response
      • 2.4.2 Self-Directed Commands -- Loopback
    • 2.5 Data Formatting/Packing Mode
    • 2.6 Maintenance Operation Protocol
    • 2.7 Error Handling
      • 2.7.1 Error Events
      • 2.7.2 Discarded Datagrams
      • 2.7.3 Event Counters
    • 2.8 Control and Status Register
    • 2.9 Network Architecture and Functional Layers
      • 2.9.1 Physical Link Layer and Data Link Layers
      • 2.9.2 Routing Layer
      • 2.9.3 End-to-End Communications Layer
      • 2.9.4 Session Control Layer
      • 2.9.5 Network Application Layer
      • 2.9.6 Network Management Layer
      • 2.9.7 User Layer
      • 2.9.8 Layer Interfaces
      • 2.9.9 Expanded ETHERNET Networks
  • Chapter 3 Installation of NIA20 in KL10-E
    • 3.1 Overview
    • 3.2 Unpacking and Checkout
    • 3.3 Equipment Needed for Installation and Checkout
    • 3.4 Installation Procedure
      • 3.4.1 Preinstallation Checkout
      • 3.4.2 Backplane Wire Adds
      • 3.4.3 Installation of Port Modules
      • 3.4.4 Power Supply Regulator Installation
      • 3.4.5 Installation of NIA20 Card Cage/Internal Cable
        • 3.4.5.1 Installation of NIA20 Current Limiter
        • 3.4.5.2 Harness Installation
      • 3.4.6 Installation of KL10 Adapter Board and Blank Module Assembly
      • 3.4.7 Checkout
  • Chapter 4 Functional Description
    • 4.1 Port States
      • 4.1.1 Uninitialized
      • 4.1.2 Disabled
      • 4.1.3 Enabled
    • 4.2 Control and Status Register
    • 4.3 EBus
      • 4.3.1 EBus Interrupts
      • 4.3.2 Examine/Desposit Request Response
    • 4.4 CBus
    • 4.5 PLI
      • 4.5.1 PLI Interface Signals
      • 4.5.2 Data (7:0) (Asserted High)
      • 4.5.3 Select (Asserted Low)
      • 4.5.4 Receiver Attention (Asserted High)
      • 4.5.5 End of Frame (Asserted High)
      • 4.5.6 Transmitter Attention (Asserted High)
      • 4.5.7 PLI/Link Control (Asserted High)
        • 4.5.7.1 Write Transmit Buffer (WT XMIT BUF)
        • 4.5.7.2 Transmit Action (FOUR COMMAND) Group
        • 4.5.7.3 Read Transmit Status (RD XMIT STATUS)
        • 4.5.7.4 Read Receive Buffer (RD REC BUF)
        • 4.5.7.5 Read Receiver Status Register (RD REC STATUS)
        • 4.5.7.6 Read Receive Memory Used Buffer Address List (RD USED BUF LST)
        • 4.5.7.7 Transfer Byte from Receive Memory to the Transmit Buffer (REC TO XMIT BUF)
        • 4.5.7.8 Reset Receive Attention (RESET REC ATT)
        • 4.5.7.9 Enable Link Control/Disable Link Control
        • 4.5.7.10 Write Receive Memory Buffer Read Address to the Read Memory Address Register (WT REC BUF RD ADRS REGISTER)
        • 4.5.7.11 Write Free Buffer List (WT FREE BUF LST)
        • 4.5.7.12 Clear Receive Buffer (CLR RCV BUF)
        • 4.5.7.13 Write Address Register (WT ADRS REG)
        • 4.5.7.14 Read Register (RD REG)
        • 4.5.7.15 Write Register (WT REG)
      • 4.5.8 Transmit Parity (Odd) (TTL Asserted High)
      • 4.5.9 Receive Data Parity (Odd) (TTL Asserted High)
      • 4.5.10 Clock Timing (PLI Bus)
      • 4.5.11 Initialize (TTL, Asserted High)
      • 4.5.12 Receive and Transmit Status
    • 4.6 Simplified NIA Block Description
      • 4.6.1 Simplified Transmit Operation
      • 4.6.2 Simplified Receive Operation
  • Chapter 5 Logic Description
    • 5.1 EBus Interface and Port ALU Module
      • 5.1.1 Introduction
      • 5.1.2 EBus Control and Status Register
      • 5.1.3 EBus Control Logic
        • 5.1.3.1 Port Microprocessor Not Running
        • 5.1.3.2 Port Microprocessor Running
          • 5.1.3.2.1 EBus Interrupts
          • 5.1.3.2.2 Examine/Deposit Request Response
      • 5.1.4 Microprocessor to EBus Register
      • 5.1.5 EBus to Microprocessor Multiplexer (EMUX)
      • 5.1.6 Microprocessor to EBus Multiplexer (KMUX)
      • 5.1.7 EBus Parity Generator
      • 5.1.8 EBus Parity Checker
      • 5.1.9 EBus Transceivers
      • 5.1.10 Arithmetic Logic Unit
      • 5.1.11 Constant Multiplexer
    • 5.2 CBus/Data Mover (CMVR) Interface Module
      • 5.2.1 CMVR Control Logic
      • 5.2.2 Data Mover and Formatter (MVR/FMTR)
      • 5.2.3 Data Input Multiplexer
      • 5.2.4 PLI Serial Up Multiplexer (SUMUX)
      • 5.2.5 PLI Serial Down Multiplexer (SDMUX)
      • 5.2.6 PLI Output Multiplexer (PMUX)
      • 5.2.7 CMVR to Microprocessor Multiplexer (CMUX)
      • 5.2.8 Microprocessor to CMVR Register (CBUF)
      • 5.2.9 CBus Input Buffer
      • 5.2.10 CBus In Parity Checker
      • 5.2.11 CBus Output Buffer
      • 5.2.12 CBus Out Parity Generator
      • 5.2.13 CBus Control Logic
      • 5.2.14 PLI Input Buffer
      • 5.2.15 PLI Parity In Checker
      • 5.2.16 PLI Output Buffer
      • 5.2.17 PLI Parity Out Generator
      • 5.2.18 PLI Control Logic
      • 5.2.19 Parity Predictor
    • 5.3 Port Microprocessor
      • 5.3.1 Condition Code Multiplexer
      • 5.3.2 Microsequencer
      • 5.3.3 RAM Address Register
      • 5.3.4 Latch Address Register
      • 5.3.5 Address Multiplexer
      • 5.3.6 Control RAM
      • 5.3.7 CRAM Load Buffers
      • 5.3.8 CRAM Parity Checker
      • 5.3.9 CRAM Register
      • 5.3.10 Microword Field Definitions
      • 5.3.11 Microword Output Multiplexer
      • 5.3.12 Jump Multiplexer
      • 5.3.13 Local Storage RAM
      • 5.3.14 RAM Mode Multiplexer
      • 5.3.15 Local Storage Address Register
      • 5.3.16 Skip Condition Field Decoder
      • 5.3.17 Microprocessor Control Logic
    • 5.4 Microcode
      • 5.4.1 Initialization
      • 5.4.2 Idle Loop
      • 5.4.3 Receive
      • 5.4.4 Transmit and Local Command
  • Appendix A Installation of NIA20 in KL10-D
    • A.1 Overview
    • A.2 Unpacking and Checkout
    • A.3 Equipment Needed for Installation and Checkout
    • A.4 Installation Procedure
      • A.4.1 Preinstallation Checkout
      • A.4.2 Backplane Wire Adds
      • A.4.3 Installation of Port Modules
      • A.4.4 Power Supply Regulator Installation
      • A.4.5 Installation of NIA20 Card Cage/Cable
        • A.4.5.1 Installation of NIA20 Current Limiter
        • A.4.5.2 Harness Installation
      • A.4.6 Installation of KL10 Adapter Board and Blank Module Assembly
      • A.4.7 Checkout
  • Appendix B Installation of NIA20 in KL10-R
    • B.1 Overview
    • B.2 Unpacking and Checkout
    • B.3 Equipment Needed for Installation and Checkout
    • B.4 Installation Procedure
      • B.4.1 Preinstallation Checkout
      • B.4.2 Backplane Wire Adds
      • B.4.3 Installation of Port Modules
      • B.4.4 Power Supply Regulator Installation
      • B.4.5 Installation of NIA20 Card Cage/Internal Cable
        • B.4.5.1 Installation of NIA2 Current Limiter
        • B.4.5.2 Harness Installation
      • B.4.6 Installation of KL10 Adaper Board and Blank Module Assembly
      • B.4.7 Checkout

Copies

Address: http://bitsavers.org/pdf/dec/pdp10/KL10/EK-NIA20-RM_Jan85.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 15437472 bytes (14.7 MiB)
MD5: 8190cdbf784e9288e15bf103bfec44d9
Mirrors: