Guide to VAX-11/780 System Troubleshooting

Company:Digital Equipment Corporation
Part:EY-2217E-SG-0001
Date:1985-11
Keywords:

Table of Contents

  • Section I VAX-11/780 Troubleshooting Outline
    • VAX-11/780 Troubleshooting Basics
    • VAX-11/780 System Troubleshooting Tools
    • VMS Operating System Crashes or Bugchecks
      • Machine Checks
        • VAX-11/780 Machine Check Error Logout
        • VMS Fatal Bugcheck/Machine Check Example
        • ESSAA Machine Check Example
        • Breakdown of VMS Machine Check Printout
        • Getting Started on Machine Checks
        • Machine Check Logout Information
        • Summary Parameter Description
        • Bit Breakdown of Stack Entries
        • Machine Check Logout Breakdown Flowchart
        • Cache Parity Errors
        • Translation Buffer Parity Errors
        • Control Store Parity Errors
        • CPU Read Timeouts/Error Confirmation
        • Read Data Substitute Faults and Aborts
        • Micro-code Not Supposed to Get Here Faults
    • CPU Double Error Halts
      • Double Error Halt Error Information
      • CPU Detected Error VALIDITY CHECKS
      • CPU DBLE-ERR HALT Flowchart
      • VAX-11/780 "ID" Register ERROR Information
      • Example of DOUBLE ERROR HALT and Hardware Dump
    • Interrupt Stack Not Valid Halts
    • Kernel Stack Not Valid Aborts
    • Other Types of Crashes
    • VMS Operating System Hangs
    • Operating System Functional Problems
    • Operating System Backup or Rebuild Problems
    • Booting Problems
      • Power-Up Booting Outline
      • Troubleshooting Booting Problems
      • Overview of LSI-11 Subsystem Bootstrapping
      • Overview of VAX CPU Bootstrapping
    • Front-End Subsystem Problems
      • LSI Subsystem Traps
      • TRAP Vector Assignments
      • LSI/PDP-11 Trap Catcher Setup Procedure
      • Power Fail Traps
      • Gathering an LSI Software DUMP
      • Analyzing LSI Software Dumps
      • LSI-Traps Software Dump Analysis Flow
      • VAX Front-end Subsystem Q-Bus Address Assignments
      • CIB Q-Bus Registers Bit Breakdown
      • PDP-11 Instruction Set
      • PDP-11 Processor Status Word Breakdown
      • PDP-11 Addressing Mode Description
    • Unexplained Reboots and Power Restarts
      • Symptoms of Spurious Reboots and Power Restarts
      • Isolating Problem Area
      • BPOK/BDCOK Connections on KA780 Backplane
      • AC/DCLO H7100 Supply Connections to KA780 Backplane
      • Voltage Pins on the KA780 Backplane
      • Q-Bus Connectors on KA780 Backplane and Wirelist
    • Problems on Certain Device(s)
    • Won't Power-Up
    • Something's Burning
    • Problems Building VMS
    • Non-Duplicatable, Intermittent and What To Do Now Problems
    • Vibration Testing
    • Operating Temperature Change Testing
      • Heat Testing
      • Testing By Cooling
    • Margin Testing
      • Clock Margins
      • Voltage Margins
    • DW780 Errors
      • SBI Parity Fault
      • SBI Write Sequence Fault
      • SBI Unexpected Read Data Fault
      • SBI Interlock Sequence Fault
      • SBI Multiple Transmitter Fault
      • Adapter Power Down
      • Adapter Power Up
      • UNIBUS Power Down
      • UNIBUS Power Up
      • Read Data Timeout
      • Read Data Substitute
      • Corrected Read Data
      • Command Transmit Error
      • Command Transmit Timeout
      • Data Path Parity Error
      • Invalid Map Register
      • Map Register Parity Fail
      • Lost Error Bit
      • UNIBUS Select Timeout
      • UNIBUS SSYN Timeout
      • Buffer Transfer Error
    • S.B.I. Faults
      • Parity Fault Description
      • Write Sequence Fault Description
      • Unexpected Read Data Fault Description
      • Interlock Sequence Fault Description
      • Multiple Transmitter Faults
      • Troubleshooting S.B.I. Faults
      • S.B.I. SILO Interpretation
      • CONFIGURATION/STATUS Register Interpretation
    • Troubleshooting Using the SYSTEM CONTROL BLOCK (SCB)
      • HALTED AT xxxxxxxx
      • Building and Using a VAX Trap Catcher
      • VMB V4.02 Trap Catcher Generation
      • ?ILL I/E VEC Errors
      • System Control Block Vector Assignments Chart
  • Section II VMS Information
    • VMS SYSGEN Error Control Parameters
      • BUGCHECKFATAL
      • BUGREBOOT
      • DUMPBUG
    • VMS Crash Handling
      • Non-Fatal Bugchecks
      • Fatal Bugchecks in Supervisor and User Modes
      • Fatal Bugchecks in Kernel and Executive Modes
    • Assigning Addresses and Vectors to UNIBUS Devices
    • UNIBUS Device Floating Address Table
    • UNIBUS Device Floating Vector Table
    • SYSGEN Commands
      • LOAD command
      • CONNECT command
      • RELOAD command
      • SHOW/ADAPTER
      • SHOW/CONFIGURATION
      • SHOW/DEVICE
      • AUTOCONFIGURE ALL
      • CONFIGURE command
      • CONNECT CONSOLE
      • CREATE command
      • DISABLE CHECKS
      • ENABLE CHECKS
      • EXIT
      • INSTALL command
      • SET/OUTUPT command
      • SET/STARTUP command
      • SHARE MPMn command
      • SHOW parameter command
      • SET parameter command
      • SHOW/UNIBUS
      • USE command
      • WRITE command
    • Using SYSGEN to determine UNIBUS device Addr/Vec Assignments
    • LOCAL CONSOLE Boot Command Files
      • DB0BOO.CMD
      • RESTART.CMD
      • DSC or BACKUP Boot Command File
      • RESTAR.ILV
      • RMEM.
  • Section III Special Command Files/Programs
    • Hardware Dump File Maintenance/Generation
    • Version 3.x VMS Dump File Generation
    • Version 4.x VMS Dump File Generation
    • DUMP. Command File
    • HANG. Command File
    • SAVEDUMP.COM Command File
    • SPEAR BATCH Command File
      • Spear Batch Control
    • SDA.COM
    • FP780 Control Programs
      • FPAOFF.MAR
      • FPAON.MAR
  • Section IV VAX-11/780 Basics
    • VAX Virtual and Physical Address Space
    • VAX-11/780 General Registers Assignments
    • Subroutine Usage and Operating
    • Procedure Usage and Operation
      • Entry Mask
      • Argument List
    • "CALLG" Procedure Call Operation
    • "CALLS" Procedure Call Operation
    • "RET" Procedure Return Operation
    • Procedure Call (CALLS/CALLG) Notes
    • Return from Procedure (RET) Notes
    • Procedure Call Stack Layout
    • VAX-11/780 Native Addressing Modes
      • Indexing Mode
      • PC Mode Addressing
  • Section V Buses Used on VAX-11/780 Systems
    • Synchronous Backplane Interconnect
      • S.B.I. Pin Layout
      • SBI/CPU Time State Equivalents
      • SBI T0 Clock Time
      • SBI T1 Clock Time
      • SBI T2 Clock Time
      • SBI T3 Clock Time
    • S.B.I. Write Transfer Example to Show S.B.I. Timing
    • VAX-11/780 Internal Data Bus
      • Chart Showing Modules Fed by the ID Bus Bits
      • ID Bus Parity Bits Chart Showing Who Uses Them
      • ID Bus KA780 Backplane Pin List
  • Section VI UNIX Error Reporting
  • Section VII Miscellaneous Information
    • Using EVSBA.EXE, the Diagnostic Autosizer
      • EVSBA Autosizer Default Mode Operation
      • Autosizer Manual or Self-test Mode Operation
      • Autosizer Commands for Manual or Self-test Mode
        • Read
        • Size
        • List
        • Help
        • Write
        • Change
        • Exit
        • Attach
    • Standard Performance Error Analysis Reporting
      • How to Initiate SPEAR
      • Summary of Questions asked by SPEAR
    • Examining UNIBUS Registers
    • LP11 Diagnostic Check Under VMS
    • To Restore LP11 Queue
    • Defining and Starting Print Queues (LP11)
    • Defining and Starting Terminal Queues
    • "Unexpected UNIBUS Adapter Interrupt
    • Interleaving Memories
    • Booting with CACHE Disabled
    • H7100 Power Regulator LEDs
    • M8232, Clock Board, Jumpers
    • LSI-11 Controls and Indicators
    • VAX-11/780 Controls and Indicators
    • MS780/MA780 Error Correction Logic
    • EVKAA.EXE
  • Section VIII NEXUS Register Bit Definitions
    • DW780 Registers
      • Configuration Register
      • Control Register
      • Status Register
      • Diagnostic Control Register
      • Failed MAP Entry Register
      • Failed UNIBUS Address Register
      • Buffer Selection Verification Registers 0-3
      • BR Receive Vector Registers 4-7
      • Data Path Register 00-15
      • MAP Registers 000-495
    • RH780 Registers
      • Configuration/Status Register
      • Control Register
      • Status Register
      • Virtual Address Register
      • Byte Count Register
      • Diagnostic Register
      • Selected MAP Register
      • Command/Address Register
    • MS780-E Registers
      • Configuration Register "A"
      • Configuration Register "B"
      • Configuration Registers "C" and "D"
      • Configuration Registers "E" and "F"

Copies

Address: http://bitsavers.org/pdf/dec/vax/780/EY-2217E-SG-0001_780tshoot.pdf
Site: Al Kossow's Bitsavers
Format: PDF
Size: 13327408 bytes (12.7 MiB)
MD5: 9092defd72c478f4b2a008d8627f9f5c
Mirrors: